Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 27, 2017, 02:14 PM
  • Wright Rd. (01-952 to 01-951) Pre Video.mp4

Date
03/27/2017
W/O
N/A
Weather
Dry
Operator/Surveyor
E. GARCIA
Sewer ID
Z00228
PipeID
P01789
Time
7:14 AM
Certificate
N/A
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
Y0740
Sewer Name
01 WRIGHT ROAD TRUNK
City
CUDAHY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Pre-Rehabilitation Survey
Project
WRIGHT_ROAD_TRUNK_REHAB
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
01 0952
Downstream MH
01 0951
Dir. of Survey
Downstream
Length Surveyed
295 ft.
Total Length
295 ft.
Structural Index
4
Structural Quick
5447
Structural Rating
57
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
57
Pipe schematic from manhole 01 0952 to 01 0951
MH: 01 0952MH: 01 0951downstream0 ft. AMH - Upstream Manhole, Survey Begins - PRE VIDEO52 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES57 ft. CM - Crack Multiple, from 06 to 07 o'clock, within 8 inches of joint: NO159 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES161 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES, Start183 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish183 ft. FH2 - Fracture Longitudinal Hinge, 2, from 12 to 06 o'clock, within 8 inches of joint: YES, Start199 ft. FH2 - Fracture Longitudinal Hinge, 2, from 12 to 06 o'clock, within 8 inches of joint: YES, Finish200 ft. FH4 - Fracture Longitudinal Hinge, 4, from 09 to 09 o'clock, within 8 inches of joint: YES, Start - FRACTURES @ 12, 3, 6 & 9220 ft. FH4 - Fracture Longitudinal Hinge, 4, from 09 to 09 o'clock, within 8 inches of joint: YES, Finish295 ft. AMH - Downstream Manhole, Survey Ends - PRE VIDEO

Observations (11)

DistanceCodeObservation
0AMHPRE VIDEO
161FM
52FL
57CM
159FL
220FH4
183FM
200FH4FRACTURES @ 12, 3, 6 & 9
199FH2
295AMHPRE VIDEO
183FH2

Properties (8)

additional_info
PRE-REHAB
custom_field_three
CRACKS AND FRACTURES THROUGHOUT
custom_field_two
1
customer
LACSD
datetime
2017-03-27T07:14:57-07:00
documentation
E. GARCIA
is_lateral_inspection
false
year_laid
19280228