Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 30, 2016, 10:16 AM
  • 15 0060_15 0059A_20160330_034737.mp4

Date
03/30/2016
W/O
563386
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00622
PipeID
P11954
Time
3:16 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3300
Sewer Name
15 PUENTE TRUNK
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
35
Purpose
Routine Assessment
Project
WO_563386_TV15025_APRIL2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
15 0060
Downstream MH
15 0059A
Dir. of Survey
Downstream
Length Surveyed
11.3 ft.
Total Length
11.3 ft.
Structural Index
4
Structural Quick
4300
Structural Rating
12
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
16
Pipe schematic from manhole 15 0060 to 15 0059A
MH: 15 0060MH: 15 0059Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 00600 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start4 ft. FM - Fracture Multiple, from 06 to 08 o'clock, within 8 inches of joint: YES7.1 ft. FM - Fracture Multiple, from 04 to 10 o'clock, within 8 inches of joint: YES, Start10.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish10.5 ft. FM - Fracture Multiple, from 04 to 10 o'clock, within 8 inches of joint: YES, Finish11.3 ft. AMH - Downstream Manhole, Survey Ends - 15 0059A

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 06 to 08 o'clock, within 8 inches of joint: YES

    4 ft. - Fracture Multiple, from 06 to 08 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 04 to 10 o'clock, within 8 inches of joint: YES, Start

    7.1 ft. - Fracture Multiple, from 04 to 10 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
10.5DAGS
0AMH15 0060
0MWL
4FM
0MWM
7.1FM
2DAGS
10.5FM
11.3AMH15 0059A

Properties (6)

additional_info
SC305426
custom_field_two
2
customer
LACSD
datetime
2016-03-30T03:16:16-07:00
documentation
PRO PIPE
is_lateral_inspection
false