Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 26, 2018, 04:20 PM
  • Section#15_02_1654_02_1653_4262018.mpg

Date
04/26/2018
W/O
N/A
Weather
Dry
Operator/Surveyor
OSCAR V.
Sewer ID
Z00292
PipeID
P18809
Time
9:20 AM
Certificate
N/A
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
Y0696
Sewer Name
02 MONTEREY PARK RELIEF TRUNK
City
MONTEREY PARK
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Post-Rehabilitation Survey
Project
20181231SHO_MONTEREY_PARK_RELIEF_TRUNK
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
02 1654
Downstream MH
02 1653
Dir. of Survey
Downstream
Length Surveyed
167.1 ft.
Total Length
167.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 02 1654 to 02 1653
MH: 02 1654MH: 02 1653downstream0 ft. AMH - Upstream Manhole, Survey Begins - POST REHAB BEGIN @ MH 16540 ft. MWL - Water Level, 5 %of cross sectional area93 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"167.1 ft. AMH - Downstream Manhole, Survey Ends - POST REHAB ENDS @ MH 1653

Observations (4)

DistanceCodeObservation
167.1AMHPOST REHAB ENDS @ MH 1653
0AMHPOST REHAB BEGIN @ MH 1654
0MWL
93TF

Properties (5)

additional_info
POST REHAB INSPECTION ONLY
custom_field_three
POST REHAB INSPECTION ONLY
custom_field_two
5
customer
LACSD
datetime
2018-04-26T09:20:57-07:00