Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 31, 2016, 08:53 AM
  • 15 1043_0_20160331_020253.mp4

Date
03/31/2016
W/O
563386
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00623
PipeID
P21857
Time
1:53 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3301
Sewer Name
15 PUENTE TRUNK CONNECTION TO J.O."H"-7B
City
INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
35
Purpose
Routine Assessment
Project
WO_563386_TV15025_APRIL2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
15 1043
Downstream MH
0
Dir. of Survey
Downstream
Length Surveyed
34 ft.
Total Length
34 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2600
O&M Rating
12
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole 15 1043 to 0
MH: 15 1043MH: 0downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 10430 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 2 O'CLOCK0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 8 O'CLOCK2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Start34 ft. AMH - Downstream Manhole, Survey Ends - CONNECTION NODE34 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
2DAGS
34AMHCONNECTION NODE
0AMH15 1043
0MWM
0MGOACTIVE CONNECTION AT MH 2 O'CLOCK
0MGOACTIVE CONNECTION AT MH 8 O'CLOCK
34DAGS

Properties (7)

additional_info
SC305427
custom_field_two
4
customer
LACSD
datetime
2016-03-31T01:53:10-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
19840418