29 0377_29 0376_08162022_050241.mp4
2.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start
2.2 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start
59 ft. - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES
126.2 ft. - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES
177.9 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES
242.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
322.4 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 0 | MWL | — |
| 332.2 | AMH | 29 0376 |
| 0 | MGO | CONNECTION AT MH 3 O'CLOCK |
| 330.1 | DAGS | — |
| 322.4 | FM | — |
| 126.2 | FM | — |
| 0 | MWM | — |
| 142.8 | TF | — |
| 59 | FM | — |
| 253.9 | TF | — |
| 2.2 | DAGS | — |
| 2.2 | SAP | — |
| 42.1 | TF | — |
| 0 | AMH | 29 0377 |
| 177.9 | FL | — |
| 246.2 | TF | — |
| 242.5 | FM | — |
| 153.2 | TF | — |
| 330.1 | SAP | — |