Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 14, 2022, 08:28 AM
  • 02 0856_02 0855_09142022_015016.mp4

Date
09/14/2022
W/O
972698
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00297
PipeID
P03423
Time
1:28 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10419
Sewer Name
02 OLD RIVER SCHOOL ROAD RELIEF TRUNK, SECTS 2&3
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_972698_TV02216_SEP2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
15 in.
Upstream MH
02 0855
Downstream MH
02 0856
Dir. of Survey
Upstream
Length Surveyed
630.2 ft.
Total Length
630.2 ft.
Structural Index
4
Structural Quick
5433
Structural Rating
29
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
29
Pipe schematic from manhole 02 0855 to 02 0856
MH: 02 0855MH: 02 0856upstream0 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 02 08562.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish4 ft. SRV - Surface Reinforcement Visible, from 07 to 08 o'clock, within 8 inches of joint: YES, Finish13.2 ft. HVV - Hole Void Visible, from 07 to 08 o'clock, within 8 inches of joint: YES20 ft. HSV - Hole Soil Visible, at 08 o'clock, within 8 inches of joint: YES20 ft. SRP - Surface Reinforcement Projecting, from 06 to 08 o'clock, within 8 inches of joint: YES20 ft. SMW - Surface Missing Wall, from 06 to 08 o'clock, within 8 inches of joint: YES548.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish548.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start585.2 ft. SRV - Surface Reinforcement Visible, from 07 to 08 o'clock, within 8 inches of joint: YES, Start628.1 ft. MGO - General Observation - MAG COAT628.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start630.2 ft. MWL - Water Level, 15 %of cross sectional area630.2 ft. AMH - Downstream Manhole, Survey Begins - 02 0855630.2 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (7)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 07 to 08 o'clock, within 8 inches of joint: YES, Start

    45 ft. - Surface Reinforcement Visible, from 07 to 08 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    82 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Hole Soil Visible, at 08 o'clock, within 8 inches of joint: YES

    610.2 ft. - Hole Soil Visible, at 08 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Projecting, from 06 to 08 o'clock, within 8 inches of joint: YES

    610.2 ft. - Surface Reinforcement Projecting, from 06 to 08 o'clock, within 8 inches of joint: YES

  • Surface Missing Wall, from 06 to 08 o'clock, within 8 inches of joint: YES

    610.2 ft. - Surface Missing Wall, from 06 to 08 o'clock, within 8 inches of joint: YES

  • Hole Void Visible, from 07 to 08 o'clock, within 8 inches of joint: YES

    617 ft. - Hole Void Visible, from 07 to 08 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
610.2HSV
2.1MGOMAG COAT
0MWL
45SRV
626.2SRV
627.9SAP
610.2SRP
0AMH02 0855
630.2MGOCONNECTION AT MH 12 O'CLOCK
610.2SMW
630.2AMH02 0856
617HVV
0MWM
82SAV
82SAP
2.1SAV

Properties (7)

additional_info
630074091322202
custom_field_three
HOLES IN PIPE REINFORCEMENT MISSING
custom_field_two
1
customer
1
datetime
2022-09-14T01:28:29-07:00
documentation
PROPIPE
is_lateral_inspection
false