Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 9, 2022, 10:23 AM
  • A 1138_A 1137_09092022_032719.mp4

Date
09/09/2022
W/O
967262
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00973
PipeID
P02789
Time
3:23 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10417
Sewer Name
A JOINT OUTFALL A - UNIT 9
City
PARAMOUNT
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
RFIR_WO_967262_TV02134_AUG2022
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
18 in.
Upstream MH
A 1137
Downstream MH
A 1138
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
5
Structural Quick
5100
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
5
Pipe schematic from manhole A 1137 to A 1138
MH: A 1137MH: A 1138upstream0 ft. MSA - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH0 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. MWL - Water Level, 25 %of cross sectional area2.1 ft. AMH - Downstream Manhole, Survey Begins - A 11372.1 ft. MWM - Water Mark, 35 %of cross sectional area2.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (2)

  • Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

    2.1 ft. - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
0MWL
0AMHA 1137
0MWM
2.1MSAVIEW OF U/S SIPHON FROM D/S MH
0MGOCONNECTION AT MH 3 O'CLOCK
2.1SRV

Properties (7)

additional_info
630074090822203
custom_field_three
AGGREGATE PROJECTING/SPALLING
custom_field_two
2
customer
1
datetime
2022-09-09T03:23:52-07:00
documentation
PROPIPE
is_lateral_inspection