Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 13, 2022, 03:29 PM
  • A 1166_A 1165_09132022_085617.mp4

Date
09/13/2022
W/O
967262
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00973
PipeID
P02816
Time
8:29 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K10372
Sewer Name
A JOINT OUTFALL A - UNIT 9
City
SOUTH GATE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
26
Purpose
Routine Assessment
Project
RFIR_WO_967262_TV02134_AUG2022
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
42 in.
Width
15 in.
Upstream MH
A 1166
Downstream MH
A 1165
Dir. of Survey
Downstream
Length Surveyed
387.2 ft.
Total Length
387.2 ft.
Structural Index
3
Structural Quick
3N2N
Structural Rating
383
O&M Index
3
O&M Quick
3N00
O&M Rating
231
Overall Index
3
Overall Quick
Overall Rating
614
Pipe schematic from manhole A 1166 to A 1165
MH: A 1166MH: A 1165downstream0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 11660 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK2.3 ft. MGO - General Observation - MAG COATING2.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.8 ft. DSC - Deposits Settled Compacted, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start8.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FALLING TILES252.9 ft. MGO - General Observation - CAMERA UNSTABLE DUE TO DEBRIS387.1 ft. DSC - Deposits Settled Compacted, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish387.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish387.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish387.2 ft. AMH - Downstream Manhole, Survey Ends - A 1165

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FALLING TILES

    8.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FALLING TILES

Observations (13)

DistanceCodeObservation
387.1DSC
2.3MGOMAG COATING
0MWM
387.2AMHA 1165
252.9MGOCAMERA UNSTABLE DUE TO DEBRIS
387.1SAP
8.5SSSFALLING TILES
0AMHA 1166
387.1SSS
2.3SAP
0MWL
0MGOCONNECTION AT THE MH 9 OC'LOCK
2.8DSC

Properties (7)

additional_info
630098091322061
custom_field_three
AGGREGATE PROJECTING/SPALLING
custom_field_two
2
customer
1
datetime
2022-09-13T08:29:45-07:00
documentation
PROPIPE
is_lateral_inspection
false