Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 21, 2022, 09:28 AM
  • 08 0321A_08 0321_09212022_023133.mp4

Date
09/21/2022
W/O
973084
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00013
PipeID
P00369
Time
2:28 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10432
Sewer Name
08 KEYSTONE TRUNK
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_973084_TV08154_SEP2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
08 0321A
Downstream MH
08 0321
Dir. of Survey
Downstream
Length Surveyed
9.1 ft.
Total Length
9.1 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 08 0321A to 08 0321
MH: 08 0321AMH: 08 0321downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 0321A0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"7.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish9.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK9.1 ft. AMH - Downstream Manhole, Survey Ends - 08 0321

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0MWL
9.1MGOCONNECTION AT MH 9 O'CLOCK
2FM
0AMH08 0321A
0MGOCONNECTION AT MH 3 O'CLOCK
6TFC
0MWM
9.1AMH08 0321
7.6FM

Properties (7)

additional_info
630074092022202
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-09-21T02:28:28-07:00
documentation
PROPIPE
is_lateral_inspection
false