Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 22, 2022, 10:41 AM
  • 08 0305_08 0304_09222022_035439.mp4

Date
09/22/2022
W/O
973084
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00013
PipeID
P00351
Time
3:41 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10435
Sewer Name
08 KEYSTONE TRUNK
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_973084_TV08154_SEP2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
12 in.
Upstream MH
08 0304
Downstream MH
08 0305
Dir. of Survey
Upstream
Length Surveyed
324.9 ft.
Total Length
324.9 ft.
Structural Index
5
Structural Quick
5141
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
9
Pipe schematic from manhole 08 0304 to 08 0305
MH: 08 0304MH: 08 0305upstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 08 03050 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish62 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"96.2 ft. B - Broken, from 10 to 02 o'clock, within 8 inches of joint: YES121.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"183.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"227.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"282 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"322.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start324.9 ft. MWM - Water Mark, 20 %of cross sectional area324.9 ft. AMH - Downstream Manhole, Survey Begins - 08 0304324.9 ft. MWL - Water Level, 10 %of cross sectional area324.9 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 10 to 02 o'clock, within 8 inches of joint: YES

    228.7 ft. - Broken, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
141.2TFC
262.9TF
42.9TF
2.8FM
228.7B
0MWM
97.6TF
203.1TFC
0AMH08 0304
324.9MGOCONNECTION AT MH 9 O'CLOCK
324.9AMH08 0305
0MWL
324.9FM
0MGOCONNECTION AT MH 3 O'CLOCK

Properties (7)

additional_info
630074092122203
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-09-22T03:41:29-07:00
documentation
PROPIPE
is_lateral_inspection
false