Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 26, 2022, 05:52 AM
  • 22 0958_22 0957_08252022_231409.mp4

Date
08/25/2022
W/O
966849
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00790
PipeID
P17328
Time
10:52 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10345
Sewer Name
22 BASE LINE TRUNK
City
GLENDORA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_966849_TV22002_AUG2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0958
Downstream MH
22 0957
Dir. of Survey
Downstream
Length Surveyed
447.9 ft.
Total Length
447.9 ft.
Structural Index
3
Structural Quick
3Q00
Structural Rating
267
O&M Index
2
O&M Quick
2Q00
O&M Rating
178
Overall Index
3
Overall Quick
Overall Rating
445
Pipe schematic from manhole 22 0958 to 22 0957
MH: 22 0958MH: 22 0957downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 22 09580 ft. MWL - Water Level, 25 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start40.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"93.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"101.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"141.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"190.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"239.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"243.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"292.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"330.3 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"342.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"445.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish445.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish447.9 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK447.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE447.9 ft. AMH - Downstream Manhole, Survey Ends - 22 0957

Observation photos (2)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • General Observation - COCKROACHES IN MANHOLE

    447.9 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (21)

DistanceCodeObservation
93.3TFC
2SAP
141.8TFC
239.5TFC
0MWM
445.8SAP
330.3TBA
0MGOCOCKROACHES IN MANHOLE
0AMH22 0958
0MWL
243.5TFC
40.1TFC
445.8DAGS
292.8TFC
447.9MGOCONNECTION AT MH 9 O'CLOCK
447.9MGOCOCKROACHES IN MANHOLE
2DAGS
342.3TFC
101.8TFC
190.8TFC
447.9AMH22 0957

Properties (7)

additional_info
630098082522201
custom_field_three
PROJECTING AGGREGATE
custom_field_two
3
customer
1
datetime
2022-08-25T22:52:44-07:00
documentation
PRO PIPE
is_lateral_inspection
false