Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 26, 2022, 05:00 AM
  • 05 0859_05 0858_08252022_232439.mp4

Date
08/25/2022
W/O
967376
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00457
PipeID
P06089
Time
10:00 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10297
Sewer Name
05 IMPERIAL HIGHWAY EXTENSION TRUNK
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_967376_TV05334_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
12 in.
Upstream MH
05 0858
Downstream MH
05 0859
Dir. of Survey
Upstream
Length Surveyed
56.1 ft.
Total Length
56.1 ft.
Structural Index
3
Structural Quick
4331
Structural Rating
19
O&M Index
4
O&M Quick
4131
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
26
Pipe schematic from manhole 05 0858 to 05 0859
MH: 05 0858MH: 05 0859upstream0 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - CAMERA UNDERWATER7.4 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start29.4 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES29.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"33.7 ft. MCU - Camera Underwater - DUE TO OFFSET JOINT38.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES41.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES45.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"47.2 ft. JOL - Joint Offset Large48.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"49.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"50.8 ft. JOL - Joint Offset Large50.8 ft. FM - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES56.1 ft. MWL - Water Level, 10 %of cross sectional area56.1 ft. MWM - Water Mark, 15 %of cross sectional area56.1 ft. AMH - Downstream Manhole, Survey Begins - 05 0858

Observation photos (8)

  • Joint Offset Large

    5.3 ft. - Joint Offset Large

  • Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

    5.3 ft. - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    6.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    7.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Joint Offset Large

    8.9 ft. - Joint Offset Large

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    14.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    17.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    26.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
0MWL
14.5CM
6.7TB
26.7FM
7.3TB
22.4MCUDUE TO OFFSET JOINT
56.1DSZ
26.5TFC
56.1MSACAMERA UNDERWATER
0MWM
17.6FM
0AMH05 0858
48.7DSZ
5.3JOL
11TF
8.9JOL
5.3FM

Properties (7)

additional_info
630074082522201
custom_field_three
Severe offset joints with broken areas of pipe
custom_field_two
2
customer
1
datetime
2022-08-25T22:00:52-07:00
documentation
PROPIPE
is_lateral_inspection
false