Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 22, 2022, 11:36 AM
  • 19 0074_C 0376_08222022_045218.mp4

Date
08/22/2022
W/O
967379
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00724
PipeID
P15106
Time
4:36 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10291
Sewer Name
19 ELAINE AVENUE TRUNK
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_967379_TV19057_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
19 0074
Downstream MH
C 0376
Dir. of Survey
Downstream
Length Surveyed
305.1 ft.
Total Length
305.1 ft.
Structural Index
3
Structural Quick
4233
Structural Rating
21
O&M Index
3
O&M Quick
4221
O&M Rating
10
Overall Index
3
Overall Quick
Overall Rating
31
Pipe schematic from manhole 19 0074 to C 0376
MH: 19 0074MH: C 0376downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 19 00740 ft. MWM - Water Mark, 60 %of cross sectional area2.7 ft. JOM - Joint Offset Medium4.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"6.6 ft. MCU - Camera Underwater - DUE TO OFFSET JOINT6.6 ft. JOM - Joint Offset Medium77.1 ft. MWLS - Water Level, Sag in pipe, 20 %of cross sectional area99.8 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start102.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"146.2 ft. FM - Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES170.3 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"205.7 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES215.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES234 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start301.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES301.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish301.5 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish305.1 ft. AMH - Downstream Manhole, Survey Ends - C 0376

Observation photos (11)

  • Joint Offset Medium

    2.7 ft. - Joint Offset Medium

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    4.9 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Water Level, Sag in pipe, 20 %of cross sectional area

    77.1 ft. - Water Level, Sag in pipe, 20 %of cross sectional area

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    99.8 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    102.2 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

    146.2 ft. - Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    170.3 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    205.7 ft. - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    215.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    234 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    301.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
77.1MWLS
99.8DAE
0MWL
205.7FM
2.7JOM
6.6MCUDUE TO OFFSET JOINT
4.9TB
146.2FM
301.5FL
170.3TB
6.6JOM
215.3CM
0AMH19 0074
0MWM
301.5CM
102.2TB
234CM
305.1AMHC 0376
301.5DAE

Properties (7)

additional_info
630074082222003
custom_field_three
CRACKS/SAGS/OFFSET JOINTS
custom_field_two
3
customer
1
datetime
2022-08-22T04:36:04-07:00
documentation
PROPIPE
is_lateral_inspection
false