Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 25, 2022, 09:36 AM
  • 30 0361_30 0360_08252022_024448.mp4

Date
08/25/2022
W/O
966854
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00854
PipeID
P17997
Time
2:36 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10296
Sewer Name
30 CLIFTON P.P. FORCE MAIN GRAVITY TRUNK
City
REDONDO BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_966854_TV30011_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
30 0361
Downstream MH
30 0360
Dir. of Survey
Downstream
Length Surveyed
179.1 ft.
Total Length
179.1 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 30 0361 to 30 0360
MH: 30 0361MH: 30 0360downstream0 ft. AMH - Upstream Manhole, Survey Begins - 30 03610 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start45.1 ft. RFJ - Roots Fine Joint, from 10 to 04 o'clock, within 8 inches of joint: YES63.3 ft. RFJ - Roots Fine Joint, from 08 to 05 o'clock, within 8 inches of joint: YES69.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"137.8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"177 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish179.1 ft. AMH - Downstream Manhole, Survey Ends - 30 0360

Observation photos (6)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 10 to 04 o'clock, within 8 inches of joint: YES

    45.1 ft. - Roots Fine Joint, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 05 o'clock, within 8 inches of joint: YES

    63.3 ft. - Roots Fine Joint, from 08 to 05 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    69.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    137.8 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

    177 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observations (10)

DistanceCodeObservation
177FM
137.8TB
45.1RFJ
0AMH30 0361
63.3RFJ
69.7TB
0MWM
2.7FM
179.1AMH30 0360
0MWL

Properties (7)

additional_info
630074082422205
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-08-25T02:36:47-07:00
documentation
PROPIPE
is_lateral_inspection
false