Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 25, 2022, 09:45 AM
  • 30 0360_30 0359_08252022_030450.mp4

Date
08/25/2022
W/O
966854
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00854
PipeID
P17996
Time
2:45 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10296
Sewer Name
30 CLIFTON P.P. FORCE MAIN GRAVITY TRUNK
City
REDONDO BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_966854_TV30011_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
30 0360
Downstream MH
30 0359
Dir. of Survey
Downstream
Length Surveyed
211.4 ft.
Total Length
211.4 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 30 0360 to 30 0359
MH: 30 0360MH: 30 0359downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 30 03604.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start119.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"146 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"161.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"205.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"211.4 ft. AMH - Downstream Manhole, Survey Ends - 30 0359211.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (5)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    119.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    146 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    161.3 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    205.4 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (10)

DistanceCodeObservation
146TB
0MWM
119.9TB
0MWL
211.4AMH30 0359
0AMH30 0360
211.4FM
161.3TB
205.4TB
4.6FM

Properties (7)

additional_info
630074082422205
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-08-25T02:45:15-07:00
documentation
PROPIPE
is_lateral_inspection
false