Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 14, 2022, 10:39 AM
  • G 0196_01 0668_09142022_034405.mp4

Date
09/14/2022
W/O
972713
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00199
PipeID
P19970
Time
3:39 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10459
Sewer Name
01 CALIFORNIA AVENUE EXTENSION TRUNK
City
LYNWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_972713_TV01010_SEP2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
01 0668
Downstream MH
G 0196
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 01 0668 to G 0196
MH: 01 0668MH: G 0196upstream0 ft. MSA - Survey Abandoned - DUE TO WATER LEVEL.0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES0 ft. FM - Fracture Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES2 ft. AMH - Downstream Manhole, Survey Begins - 01 06682 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (3)

  • Survey Abandoned - DUE TO WATER LEVEL.

    2 ft. - Survey Abandoned - DUE TO WATER LEVEL.

  • Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES

  • Fracture Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES

    2 ft. - Fracture Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES

Observations (5)

DistanceCodeObservation
2MSADUE TO WATER LEVEL.
2DAGS
0AMH01 0668
2FM
0MWL

Properties (7)

additional_info
630138091322203
custom_field_three
ABANDONED DUE TO WATER LEVEL/MULTIPLE FRACTURES
custom_field_two
5
customer
1
datetime
2022-09-14T03:39:08-07:00
documentation
PRO PIPE
is_lateral_inspection
false