Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 15, 2022, 09:27 AM
  • 16 0195_16 0179_09152022_023100.mp4

Date
09/15/2022
W/O
972487
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00647
PipeID
P13240
Time
2:27 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10422
Sewer Name
16 ARROYO SECO TRUNK, SECTION 4
City
S.PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Routine Assessment
Project
WO_972487_TV16012_SEP2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
16 0195
Downstream MH
16 0179
Dir. of Survey
Downstream
Length Surveyed
86.2 ft.
Total Length
86.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 16 0195 to 16 0179
MH: 16 0195MH: 16 0179downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 01950 ft. MWL - Water Level, 15 %of cross sectional area3.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start31 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"84.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish86.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK86.2 ft. AMH - Downstream Manhole, Survey Ends - 16 0179

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
84.7SAV
0MWM
31TFA
0AMH16 0195
86.2MGOCONNECTION AT MH 9 O'CLOCK
3.9SAV
0MWL
86.2AMH16 0179

Properties (7)

additional_info
630074091422202
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2022-09-15T02:27:05-07:00
documentation
PROPIPE
is_lateral_inspection
false