Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 12, 2022, 11:33 AM
  • 29 0036_C 0622_07122022_045119.mp4

Date
07/12/2022
W/O
962011
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00020
PipeID
P23816
Time
4:33 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9977
Sewer Name
29 EASTSIDE INTERCEPTOR TRUNK
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_962011_TV29109_JUL2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
29 0036
Downstream MH
C 0622
Dir. of Survey
Downstream
Length Surveyed
255.1 ft.
Total Length
255.1 ft.
Structural Index
2
Structural Quick
3324
Structural Rating
17
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
18
Pipe schematic from manhole 29 0036 to C 0622
MH: 29 0036MH: C 0622downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 00364.1 ft. CM - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES42.2 ft. CS - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES116 ft. MMC - Material Change, Reinforced concrete pipe116.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start117.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start128.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish128.8 ft. MMC - Material Change, Vitrified clay pipe128.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish211.4 ft. LD - Alignment Down, 10 %255.1 ft. AMH - Downstream Manhole, Survey Ends - C 0622

Observation photos (7)

  • Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

    4.1 ft. - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

    42.2 ft. - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

  • Material Change, Reinforced concrete pipe

    116 ft. - Material Change, Reinforced concrete pipe

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    116.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    117.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Material Change, Vitrified clay pipe

    128.8 ft. - Material Change, Vitrified clay pipe

  • Alignment Down, 10 %

    211.4 ft. - Alignment Down, 10 %

Observations (13)

DistanceCodeObservation
117.2SAP
128.8MMC
0MWL
128.7SAP
0MWM
116.2SSS
116MMC
0AMH29 0036
211.4LD
4.1CM
128.8SSS
42.2CS
255.1AMHC 0622

Properties (7)

additional_info
630074071222052
custom_field_three
CRACKS, AGGREGATE PRJECTING, SPALLING
custom_field_two
3
customer
1
datetime
2022-07-12T04:33:27-07:00
documentation
PRO PIPE
is_lateral_inspection
false