- Date
- 08/22/2022
- W/O
- 967380
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00891
- PipeID
- P19920
- Time
- 2:33 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10338
- Sewer Name
- 32 VALENCIA TRUNK
- City
- SANTA CLARITA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 32
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- RFIR_WO_967380_TV32044_AUG2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 32 0169
- Downstream MH
- 32 0168
- Dir. of Survey
- Downstream
- Length Surveyed
- 155.7 ft.
- Total Length
- 155.7 ft.
- Structural Index
- 3
- Structural Quick
- 413E
- Structural Rating
- 91
- O&M Index
- 2
- O&M Quick
- 2I00
- O&M Rating
- 104
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 195
Pipe schematic from manhole 32 0169 to 32 0168 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

4.4 ft. - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

13.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

44.2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start

149.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES