- Date
- 09/12/2022
- W/O
- 966855
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00039
- PipeID
- P10212
- Time
- 10:09 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10453
- Sewer Name
- F JOINT OUTFALL F - UNIT 4
- City
- NORWALK
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 33
- Purpose
- Routine Assessment
- Project
- RFIR_WO_966855_TV02265_AUG2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 33 in.
- Width
- 24 in.
- Upstream MH
- F 0277
- Downstream MH
- F 0096
- Dir. of Survey
- Downstream
- Length Surveyed
- 298.2 ft.
- Total Length
- 298.2 ft.
- Structural Index
- 3
- Structural Quick
- 5131
- Structural Rating
- 10
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 14
Pipe schematic from manhole F 0277 to F 0096 Observation photos (4)

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

298.2 ft. - General Observation - COCKROACHES IN MH