- Date
- 08/25/2022
- W/O
- 967393
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00019
- PipeID
- P00543
- Time
- 1:40 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10295
- Sewer Name
- 08 SEPULVEDA-FIGUEROA STREET CONNECTING TRUNK
- City
- CARSON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- RFIR_WO_967393_TV08165_AUG2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 36 in.
- Upstream MH
- 08 0485
- Downstream MH
- 08 0484
- Dir. of Survey
- Downstream
- Length Surveyed
- 221.4 ft.
- Total Length
- 221.4 ft.
- Structural Index
- 4
- Structural Quick
- 4232
- Structural Rating
- 14
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 14
Pipe schematic from manhole 08 0485 to 08 0484 Observation photos (4)

3.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

5.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

7.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

58.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start