Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 31, 2022, 04:42 AM
  • 29 0146A_29 0146_08302022_215116.mp4

Date
08/30/2022
W/O
967390
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00378
PipeID
P24041
Time
9:42 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10299
Sewer Name
29 REDONDO AVENUE TRUNK
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_967390_TV29061_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
29 0146A
Downstream MH
29 0146
Dir. of Survey
Downstream
Length Surveyed
131.9 ft.
Total Length
131.9 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 29 0146A to 29 0146
MH: 29 0146AMH: 29 0146downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 0146A0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 10 %of cross sectional area22.2 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"28.8 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES66.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES73.7 ft. H - Hole, at 12 o'clock, within 8 inches of joint: NO111 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES131.9 ft. AOC - Drop Connection, Survey Ends - 29 0146

Observation photos (4)

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    28.8 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    66.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Hole, at 12 o'clock, within 8 inches of joint: NO

    73.7 ft. - Hole, at 12 o'clock, within 8 inches of joint: NO

  • Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

    111 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
131.9AOC29 0146
0MWL
0AMH29 0146A
73.7H
22.2TF
0MGOCONNECTION AT MH 3 O'CLOCK
111FC
0MWM
28.8CL
66.6FL

Properties (7)

additional_info
630074083022201
custom_field_three
FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-08-30T21:42:22-07:00
documentation
PROPIPE
is_lateral_inspection
false