- Date
- 08/22/2022
- W/O
- 967331
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00729
- PipeID
- P15191
- Time
- 3:09 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10290
- Sewer Name
- 19 WEST ARTESIA TRUNK
- City
- CERRITOS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- RFIR_WO_967331_TV19028_AUG2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 19 0222
- Downstream MH
- 19 0221
- Dir. of Survey
- Downstream
- Length Surveyed
- 124.5 ft.
- Total Length
- 124.5 ft.
- Structural Index
- 3
- Structural Quick
- 3D2D
- Structural Rating
- 120
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 122
Pipe schematic from manhole 19 0222 to 19 0221 Observation photos (3)

2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

12.2 ft. - Tap Saddle Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - ACTIVE.