Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2022, 06:44 PM
  • 29 0212_29 0211_08092022_120509.mp4

Date
08/09/2022
W/O
966940
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01026
PipeID
P24114
Time
11:44 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K10355
Sewer Name
29 28TH STREET PUMPING PLANT SEWER
City
SIGNAL HILL
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_966940_TV29123_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0211
Downstream MH
29 0212
Dir. of Survey
Upstream
Length Surveyed
253.4 ft.
Total Length
253.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 29 0211 to 29 0212
MH: 29 0211MH: 29 0212upstream0 ft. AMH - Upstream Manhole, Survey Ends - 29 02126.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"14.5 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"39.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish42.8 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"52.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start91.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"113.9 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"141.7 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"164.5 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"192.4 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"215.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"238.2 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"253.4 ft. AMH - Downstream Manhole, Survey Begins - 29 0211253.4 ft. MWL - Water Level, 5 %of cross sectional area253.4 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    201.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
38.1TFC
213.5DAGS
0AMH29 0211
0MWL
238.9TFC
201.3DAGS
88.9TFC
162.3TFC
61TFC
111.7TFC
15.2TFC
210.6TF
247.1TFA
0MWM
253.4AMH29 0212
139.5TFC

Properties (7)

additional_info
630098080922062
custom_field_three
NO STRUCTURAL DEFECT
custom_field_two
3
customer
1
datetime
2022-08-09T11:44:03-07:00
documentation
PROPIPE
is_lateral_inspection
false