Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2022, 02:37 PM
  • 29 0209_29 0208_08102022_080207.mp4

Date
08/10/2022
W/O
966940
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01026
PipeID
P24111
Time
7:37 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K10356
Sewer Name
29 28TH STREET PUMPING PLANT SEWER
City
SIGNAL HILL
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_966940_TV29123_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Rectangular
Height
8 in.
Width
8 in.
Upstream MH
29 0209
Downstream MH
29 0208
Dir. of Survey
Downstream
Length Surveyed
302.9 ft.
Total Length
302.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 29 0209 to 29 0208
MH: 29 0209MH: 29 0208downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 02090 ft. MWM - Water Mark, 15 %of cross sectional area27.4 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 4"50.2 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"74 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"90.7 ft. FS - Fracture Spiral, from 05 to 08 o'clock, within 8 inches of joint: YES91.5 ft. TFD - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: NO, 4" - BROKEN CAP104.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"152.9 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"175.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"198.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"261.3 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"302.9 ft. AMH - Downstream Manhole, Survey Ends - 29 0208

Observation photos (2)

  • Fracture Spiral, from 05 to 08 o'clock, within 8 inches of joint: YES

    90.7 ft. - Fracture Spiral, from 05 to 08 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: NO, 4" - BROKEN CAP

    91.5 ft. - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: NO, 4" - BROKEN CAP

Observations (14)

DistanceCodeObservation
302.9AMH29 0208
175.1TFC
50.2TF
27.4TFA
261.3TFC
0MWL
198.1TFC
0AMH29 0209
104.1TFC
74TFC
90.7FS
91.5TFDBROKEN CAP
152.9TF
0MWM

Properties (7)

additional_info
630098081022061
custom_field_three
FRACTURED
custom_field_two
2
customer
1
datetime
2022-08-10T07:37:08-07:00
documentation
PROPIPE
is_lateral_inspection
false