Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 31, 2022, 07:32 AM
  • 05 2000_05 1999_08312022_012726.mp4

Date
08/31/2022
W/O
967072
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00538
PipeID
P07192
Time
12:32 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10403
Sewer Name
05 WESTERN AVENUE TRUNK
City
RANCHO PALOS VERDES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
44
Purpose
Routine Assessment
Project
WO_967072_TV05381_AUG2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
15 in.
Upstream MH
05 2000
Downstream MH
05 1999
Dir. of Survey
Downstream
Length Surveyed
376 ft.
Total Length
376 ft.
Structural Index
3
Structural Quick
3600
Structural Rating
18
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
20
Pipe schematic from manhole 05 2000 to 05 1999
MH: 05 2000MH: 05 1999downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 20002.1 ft. MGO - General Observation - PIPE IS LINED60.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"106 ft. LFBU - Lining Failure Bulges, at 10 o'clock, within 8 inches of joint:UNKNOWN188.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"229.3 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES297 ft. LFBU - Lining Failure Bulges, at 01 o'clock, within 8 inches of joint:UNKNOWN,Start311 ft. LFBU - Lining Failure Bulges, at 01 o'clock, within 8 inches of joint: UNKNOWN, Finish347 ft. LFBU - Lining Failure Bulges, at 02 o'clock, within 8 inches of joint: UNKNOWN, Start351 ft. LFBU - Lining Failure Bulges, at 02 o'clock, within 8 inches of joint: UNKNOWN, Finish376 ft. AMH - Downstream Manhole, Survey Ends - 05 1999

Observation photos (1)

  • Deposits Settled Fine,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES

    229.3 ft. - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
351LFBU
376AMH05 1999
106LFBU
0MWL
60.5TF
229.3DSF
347LFBU
311LFBU
297LFBU
0MWM
2.1MGOPIPE IS LINED
0AMH05 2000
188.7TF

Properties (8)

additional_info
630074083022204
custom_field_three
NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2022-08-31T00:32:58-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
PEP-Deformed/Reformed