Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2022, 06:11 AM
  • 18 0788_18 0787_05172022_232048.mp4

Date
05/17/2022
W/O
951939
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14646
Time
11:11 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10100
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_951939_TV18053_MAY2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
18 0788
Downstream MH
18 0787
Dir. of Survey
Downstream
Length Surveyed
268.6 ft.
Total Length
268.6 ft.
Structural Index
2
Structural Quick
2J00
Structural Rating
106
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
106
Pipe schematic from manhole 18 0788 to 18 0787
MH: 18 0788MH: 18 0787downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 07880 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area4.7 ft. MGO - General Observation - MAG COAT5 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start268 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish268.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK268.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0787

Observations (10)

DistanceCodeObservation
268SSS
268.6MGOCONNECTION AT MH 9 O'CLOCK
0MGOCONNECTION AT MH 9 O'CLOCK
0AMH18 0788
0MWM
0MGOCONNECTION AT MH 3 O'CLOCK
4.7MGOMAG COAT
0MWL
268.6AMH18 0787
5SSS

Properties (7)

additional_info
630074051722202
custom_field_three
NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2022-05-17T23:11:11-07:00
documentation
PROPIPE
is_lateral_inspection
false