Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 11, 2022, 12:52 PM
  • 18 0904_18 0903_07112022_055843.mp4

Date
07/11/2022
W/O
951939
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00706
PipeID
P14607
Time
5:52 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9975
Sewer Name
18 SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
WO_951939_TV18053_MAY2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
18 0903
Downstream MH
18 0904
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 18 0903 to 18 0904
MH: 18 0903MH: 18 0904upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 0904 ZOOMED IN0 ft. MGO - General Observation - UNABLE TO PASS PLUG/CABLES IN MANHOLE2 ft. MWL - Water Level, 40 %of cross sectional area2 ft. AMH - Downstream Manhole, Survey Begins - 18 09032 ft. MWM - Water Mark, 60 %of cross sectional area

Observation photos (1)

  • General Observation - UNABLE TO PASS PLUG/CABLES IN MANHOLE

    2 ft. - General Observation - UNABLE TO PASS PLUG/CABLES IN MANHOLE

Observations (5)

DistanceCodeObservation
0MWL
0AMH18 0903
0MWM
2AMH18 0904 ZOOMED IN
2MGOUNABLE TO PASS PLUG/CABLES IN MANHOLE

Properties (7)

additional_info
630074071122001
custom_field_three
PLUG/CABLES IN D/S MANHOLE
custom_field_two
5
customer
1
datetime
2022-07-11T05:52:57-07:00
documentation
PROPIPE
is_lateral_inspection
false