Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 15, 2022, 10:25 AM
  • 01 0226_01 0225_08152022_033851.mp4

Date
08/15/2022
W/O
967226
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01268
Time
3:25 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10284
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_967226_TV01011_AUG2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
15 in.
Upstream MH
01 0226
Downstream MH
01 0225
Dir. of Survey
Downstream
Length Surveyed
305 ft.
Total Length
305 ft.
Structural Index
4
Structural Quick
4331
Structural Rating
15
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
15
Pipe schematic from manhole 01 0226 to 01 0225
MH: 01 0226MH: 01 0225downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 02260 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.2 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES25.9 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES31.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES71.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"96.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"122.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"137 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"172.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"175.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"182.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"222.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"258.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"276 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"298.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"304.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish305 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK305 ft. AMH - Downstream Manhole, Survey Ends - 01 0225

Observation photos (4)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    2.2 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    25.9 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    31.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
0.1MGOCONNECTION AT MH 9 O'CLOCK
182.8TF
137TF
0AMH01 0226
25.9FM
276TF
258.4TF
31.5FM
304.9SAP
2.1SAP
305MGOCONNECTION AT MH 9 O'CLOCK
0MWL
96.8TF
122.2TF
0MWM
298.8TF
222.7TF
175.2TF
305AMH01 0225
172.2TF
2.2FM
71.5TF

Properties (7)

additional_info
630074081522003
custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2022-08-15T03:25:12-07:00
documentation
PROPIPE
is_lateral_inspection
false