Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 12, 2022, 07:09 AM
  • 01 0218_01 0217_08122022_003025.mp4

Date
08/12/2022
W/O
967226
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01260
Time
12:09 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10281
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_967226_TV01011_AUG2022
Sewer Type
Gravity
Material
NRCP
Shape
Square
Height
12 in.
Width
15 in.
Upstream MH
01 0218
Downstream MH
01 0217
Dir. of Survey
Downstream
Length Surveyed
326 ft.
Total Length
326 ft.
Structural Index
3
Structural Quick
4131
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 01 0218 to 01 0217
MH: 01 0218MH: 01 0217downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 02180 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.6 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES11.7 ft. FM - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES47.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"53.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"72.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"89 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"129.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"137.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"167.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"190.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"194.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"218.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"235.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"241.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"254 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"300.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"324.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish326 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK326 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK326 ft. AMH - Downstream Manhole, Survey Ends - 01 0217

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

    4.6 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    11.7 ft. - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
324.4SAP
167.3TF
89TF
235.9TF
326MGOCONNECTION AT MH 3 O'CLOCK
4.6FC
241.2TF
129.9TF
11.7FM
137.9TF
190.4TF
47.7TF
300.2TF
326MGOCONNECTION AT MH 9 O'CLOCK
53.8TF
194.1TF
0AMH01 0218
326AMH01 0217
0MWL
72.2TF
0MWM
2.1SAP
0MGOCONNECTION AT MH 9 O'CLOCK
218.5TF
254TF

Properties (7)

additional_info
630074081122203
custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2022-08-12T00:09:53-07:00
documentation
PROPIPE
is_lateral_inspection
false