Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 11, 2022, 08:08 AM
  • 01 0212_01 0211_08112022_012855.mp4

Date
08/11/2022
W/O
967226
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01254
Time
1:08 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10276
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_967226_TV01011_AUG2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
01 0212
Downstream MH
01 0211
Dir. of Survey
Downstream
Length Surveyed
348.1 ft.
Total Length
348.2 ft.
Structural Index
3
Structural Quick
4435
Structural Rating
33
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
34
Pipe schematic from manhole 01 0212 to 01 0211
MH: 01 0212MH: 01 0211downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 02120 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK2.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"8.7 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES36.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES42.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"67.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"83.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"96.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"121.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"136.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"160.5 ft. RFJ - Roots Fine Joint, from 09 to 11 o'clock, within 8 inches of joint: YES161.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"164.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"210 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"218.9 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES227.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"240.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"241.8 ft. FM - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES264.6 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES268.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"280.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"285.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"307.2 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES312.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES323.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"337.6 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES340.2 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES348.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK348.2 ft. AMH - Downstream Manhole, Survey Ends - 01 0211348.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (10)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    8.7 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    36.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    218.9 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    241.8 ft. - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    264.6 ft. - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    307.2 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    312.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    337.6 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    340.2 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (34)

DistanceCodeObservation
136.6TF
227.8TF
0AMH01 0212
7.5TF
312.2FL
268.3TF
280.6TF
2.6SAP
264.6FM
348.2MGOCONNECTION AT MH 9 O'CLOCK
218.9FL
164.7TF
348.2AMH01 0211
210TF
67.8TF
0MWL
121.6TF
337.6FL
241.8FM
36.6CL
240.4TF
8.7FM
83.9TF
348.2SAP
0MWM
96.2TF
160.5RFJ
307.2FL
0MGOCONNECTION AT MH 9 O'CLOCK
42.9TF
285.8TF
161.7TF
323.4TF
340.2FM

Properties (7)

additional_info
630074081022202
custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2022-08-11T01:08:38-07:00
documentation
PROPIPE
is_lateral_inspection
false