- Date
- 08/24/2022
- W/O
- 967395
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00767
- PipeID
- P15802
- Time
- 11:17 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10343
- Sewer Name
- 21 FIRST ST TR, SECT 1A & CONNS TO 1ST ST TR SYSTM
- City
- POMONA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_967395_TV21099_AUG2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 21 0649
- Downstream MH
- 21 0138
- Dir. of Survey
- Downstream
- Length Surveyed
- 318.7 ft.
- Total Length
- 318.7 ft.
- Structural Index
- 3
- Structural Quick
- 3L2L
- Structural Rating
- 315
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 315
Pipe schematic from manhole 21 0649 to 21 0138 Observation photos (5)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - General Observation - MAG COATING

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

318.7 ft. - General Observation - COCKROACHES IN MANHOLE