Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 23, 2022, 11:06 AM
  • 15 0858_15 0857_9232022_041007.mp4

Date
09/23/2022
W/O
PENDING
Weather
Dry
Operator/Surveyor
BRAR
Sewer ID
Z00594
PipeID
P12636
Time
4:06 AM
Certificate
SEE REMARKS
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H 3211
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
City
SIERRA MADRE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Routine Assessment
Project
20220923_SB_AR_SI_MAD_TR_SEC_3_2A
Sewer Type
SS
Material
NRCP
Shape
Circular
Height
9.300000190734863 in.
Upstream MH
15 0858
Downstream MH
15 0857
Dir. of Survey
Downstream
Length Surveyed
333 ft.
Total Length
333 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3121
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 15 0858 to 15 0857
MH: 15 0858MH: 15 0857downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15.08580 ft. MWL - Water Level, 5 %of cross sectional area5.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 04 o'clock, , within 8 inches of joint: YES, Start47 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"47 ft. RML - Roots Medium Lateral, from 07 to 10 o'clock, 15 %, within 8 inches of joint: YES - IN SEWER TRUNK331.2 ft. MGO - General Observation - LINED PIPE331.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 04 o'clock, , within 8 inches of joint: YES, Finish333 ft. AMH - Downstream Manhole, Survey Ends - 15.0857, 4:32 AM

Observations (9)

DistanceCodeObservation
331.2MGOLINED PIPE
0MWM
0AMH15.0858
0MWL
47TF
333AMH15.0857, 4:32 AM
47RMLIN SEWER TRUNK
5.1DAGS
331.2DAGS

Properties (8)

additional_info
U-0618-0703002249
custom_field_three
ROOTS, GREASE
custom_field_two
4
customer
LACSD
datetime
2022-09-23T04:06:34-07:00
documentation
BRAR, CASTILLO, OLIVER
is_lateral_inspection
false
lining
CIPP