Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 1, 2022, 09:25 AM
  • 01 1199_01 1198_09012022_023859.mp4

Date
09/01/2022
W/O
966851
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00226
PipeID
P02109
Time
2:25 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10409
Sewer Name
01 WILCOX AVENUE TRUNK, EXTENSION #1
City
CUDAHY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_966851_TV01250_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 1198
Downstream MH
01 1199
Dir. of Survey
Upstream
Length Surveyed
304.9 ft.
Total Length
304.9 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 01 1198 to 01 1199
MH: 01 1198MH: 01 1199upstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 01 11990 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish301.8 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start304.9 ft. AMH - Downstream Manhole, Survey Begins - 01 1198304.9 ft. MWL - Water Level, 10 %of cross sectional area304.9 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (1)

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
304.9MGOCONNECTION AT MH 9 O'CLOCK
3.1FM
304.9MGOCONNECTION AT MH 3 O'CLOCK
0AMH01 1198
0MWL
304.9AMH01 1199
304.9FM
0MWM

Properties (7)

additional_info
630074083122204
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-09-01T02:25:33-07:00
documentation
PROPIPE
is_lateral_inspection
false