Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 15, 2022, 04:28 AM
  • 08 0270_08 0269_07142022_214841.mp4

Date
07/14/2022
W/O
962067
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00004
PipeID
P00312
Time
9:28 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9981
Sewer Name
08 DEL AMO TRUNK
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_962067_TV08167_JUL2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
08 0270
Downstream MH
08 0269
Dir. of Survey
Downstream
Length Surveyed
349.6 ft.
Total Length
349.7 ft.
Structural Index
3
Structural Quick
413L
Structural Rating
203
O&M Index
2
O&M Quick
2C12
O&M Rating
38
Overall Index
3
Overall Quick
Overall Rating
241
Pipe schematic from manhole 08 0270 to 08 0269
MH: 08 0270MH: 08 0269downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 02704 ft. CS - Crack Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES5.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES9.1 ft. FM - Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES21 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start115.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"118.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"231.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"233.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"259.8 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start318.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"322 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"327.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES330.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish330.6 ft. CS - Crack Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES343.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES348.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish349.6 ft. VC - Vermin Cockroach349.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK349.7 ft. AMH - Downstream Manhole, Survey Ends - 08 0269

Observation photos (8)

  • Crack Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES

    4 ft. - Crack Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    5.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

    9.1 ft. - Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    21 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    259.8 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    327.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

    330.6 ft. - Crack Spiral, from 04 to 06 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    343.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
115.9TFC
349.7MGOCONNECTION AT MH 3 O'CLOCK
233.9TFC
343.5FL
4CS
259.8DAE
118.8TFC
0MWL
0VC
322TFC
348.1DAE
0MWM
330.5CM
349.7AMH08 0269
318.1TFC
231.7TFC
21CM
0AMH08 0270
327.6FL
330.6CS
349.6VC
9.1FM
5.1CM

Properties (7)

additional_info
630074071422201
custom_field_three
FRACTURE, ENCRUSTATION
custom_field_two
3
customer
1
datetime
2022-07-14T21:28:08-07:00
documentation
PRO PIPE
is_lateral_inspection
false