Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2022, 04:42 AM
  • G 0212_G 0211_08082022_223127.mp4

Date
08/08/2022
W/O
962071
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01180
PipeID
P01116
Time
9:42 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10267
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
SOUTH GATE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_962071_TV01122_JUL2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
24 in.
Upstream MH
G 0212
Downstream MH
G 0211
Dir. of Survey
Downstream
Length Surveyed
332.7 ft.
Total Length
332.7 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole G 0212 to G 0211
MH: G 0212MH: G 0211downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - G 02120 ft. MWM - Water Mark, 30 %of cross sectional area11.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES17.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start38.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start38.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish48.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start66.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"77.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish114.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"165.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"213.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"261.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"305 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"332.7 ft. AMH - Downstream Manhole, Survey Ends - G 0211332.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish332.7 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK332.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (4)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    11.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    17.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    38.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    48.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (20)

DistanceCodeObservation
0MGOCONNECTION AT MH 3 O'CLOCK
38.8CM
66.5TFC
0MWL
17.1CL
38.8CL
11.7CL
48.8FL
332.7AMHG 0211
0AMHG 0212
114.3TFC
213.5TFC
332.7CM
261.8TFC
0MWM
165.7TFC
305TFC
332.7MGOCONNECTION AT MH 9 O'CLOCK
77.6FL
332.7MGOCONNECTION AT MH 3 O'CLOCK

Properties (7)

additional_info
630074080822201
custom_field_three
CRACKS/FRACTURE'S
custom_field_two
3
customer
1
datetime
2022-08-08T21:42:12-07:00
documentation
PROPIPE
is_lateral_inspection
false