Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2022, 07:23 AM
  • G 0181_G 0180_08092022_003147.mp4

Date
08/09/2022
W/O
962071
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01180
PipeID
P01086
Time
12:23 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10267
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
LYNWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_962071_TV01122_JUL2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
G 0181
Downstream MH
G 0180
Dir. of Survey
Downstream
Length Surveyed
97.4 ft.
Total Length
97.4 ft.
Structural Index
3
Structural Quick
4122
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole G 0181 to G 0180
MH: G 0181MH: G 0180downstream0 ft. AMH - Upstream Manhole, Survey Begins - G 01810 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area11.3 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES15.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES91 ft. FM - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES97.4 ft. AMH - Downstream Manhole, Survey Ends - G 0180

Observation photos (2)

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    11.3 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

    91 ft. - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
97.4AMHG 0180
0AMHG 0181
11.3CL
0MWM
15.8CL
91FM
0MWL

Properties (7)

additional_info
630074080822201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-08-09T00:23:37-07:00
documentation
PROPIPE
is_lateral_inspection
false