- Date
- 08/05/2022
- W/O
- 962071
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z01180
- PipeID
- P01082
- Time
- 1:55 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K10350
- Sewer Name
- G JOINT OUTFALL G - UNIT 8
- City
- COMPTON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 16
- Purpose
- Routine Assessment
- Project
- RFIR_WO_962071_TV01122_JUL2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 21 in.
- Upstream MH
- G 0177
- Downstream MH
- G 0176
- Dir. of Survey
- Downstream
- Length Surveyed
- 332.5 ft.
- Total Length
- 332.5 ft.
- Structural Index
- 2
- Structural Quick
- 3121
- Structural Rating
- 6
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 132
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 138
Pipe schematic from manhole G 0177 to G 0176 Observation photos (4)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

10 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

270.6 ft. - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

312.1 ft. - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES