Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 17, 2022, 04:52 AM
  • 01 0254_01 0253_08162022_220330.mp4

Date
08/16/2022
W/O
967125
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00218
PipeID
P01299
Time
9:52 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10285
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_967125_TV01205_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
27 in.
Upstream MH
01 0254
Downstream MH
01 0253
Dir. of Survey
Downstream
Length Surveyed
267.5 ft.
Total Length
267.5 ft.
Structural Index
3
Structural Quick
4131
Structural Rating
9
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 01 0254 to 01 0253
MH: 01 0254MH: 01 0253downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 02540 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area5.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start19 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES20.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start110.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"152.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"180 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"213 ft. RFJ - Roots Fine Joint, from 10 to 02 o'clock, within 8 inches of joint: YES244.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"266 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"267 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish267.5 ft. AMH - Downstream Manhole, Survey Ends - 01 0253267.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (4)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    19 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    20.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 10 to 02 o'clock, within 8 inches of joint: YES

    213 ft. - Roots Fine Joint, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
0AMH01 0254
244.4TF
0MGOCONNECTION AT MH 3 O'CLOCK
152.9TF
213RFJ
266TF
5.7SSS
20.1FM
19CM
267FM
110.4TFC
267.5AMH01 0253
0MWL
180TF
267.5SSS
0MWM

Properties (7)

additional_info
630074081622201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-08-16T21:52:04-07:00
documentation
PROPIPE
is_lateral_inspection
false