Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2022, 10:04 AM
  • 16 0176_16 0175_08102022_031524.mp4

Date
08/10/2022
W/O
967378
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00648
PipeID
P13208
Time
3:04 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10320
Sewer Name
16 ARROYO SECO TRUNK, SECTION 5
City
SOUTH PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_967378_TV16081_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Width
16 in.
Upstream MH
16 0175
Downstream MH
16 0176
Dir. of Survey
Upstream
Length Surveyed
5.7 ft.
Total Length
5.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 16 0175 to 16 0176
MH: 16 0175MH: 16 0176upstream0 ft. MSA - Survey Abandoned - DUE TO TURN AT ABANDONED MH.0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish1.8 ft. MGO - General Observation - ABANDONED MH3.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start5.7 ft. AMH - Downstream Manhole, Survey Begins - 16 01755.7 ft. MWL - Water Level, 5 %of cross sectional area5.7 ft. MWM - Water Mark, 10 %of cross sectional area5.7 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE

Observation photos (1)

  • General Observation - ABANDONED MH

    3.9 ft. - General Observation - ABANDONED MH

Observations (8)

DistanceCodeObservation
0AMH16 0175
2DAGS
0MWL
5.7MSADUE TO TURN AT ABANDONED MH.
0MWM
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
5.7DAGS
3.9MGOABANDONED MH

Properties (7)

additional_info
630098080922202
custom_field_three
ABANDONED DUE TO TURN AT ABANDONED MH
custom_field_two
5
customer
1
datetime
2022-08-10T03:04:01-07:00
documentation
PRO PIPE
is_lateral_inspection
false