- Date
- 08/10/2022
- W/O
- 967330
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00528
- PipeID
- P06738
- Time
- 3:22 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10274
- Sewer Name
- 05 TORRANCE EXTENSION TRUNK
- City
- TORRANCE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 29
- Purpose
- Routine Assessment
- Project
- RFIR_WO_967330_TV05210_AUG2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 10 in.
- Width
- 15 in.
- Upstream MH
- 05 1516
- Downstream MH
- 05 1515
- Dir. of Survey
- Downstream
- Length Surveyed
- 369.2 ft.
- Total Length
- 369.2 ft.
- Structural Index
- 3
- Structural Quick
- 4132
- Structural Rating
- 10
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole 05 1516 to 05 1515 Observation photos (3)

7.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

124.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

331.8 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES