- Date
- 08/17/2022
- W/O
- 967355
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00583
- PipeID
- P18373
- Time
- 12:55 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10332
- Sewer Name
- 14 TRUNK "F"
- City
- LANCASTER
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 16
- Purpose
- Routine Assessment
- Project
- RFIR_WO_967355_TV14076_AUG2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 14 0306A
- Downstream MH
- 14 0306
- Dir. of Survey
- Downstream
- Length Surveyed
- 349.3 ft.
- Total Length
- 349.3 ft.
- Structural Index
- 2
- Structural Quick
- 3J2M
- Structural Rating
- 297
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 297
Pipe schematic from manhole 14 0306A to 14 0306 Observation photos (3)

2 ft. - General Observation - MAG COATING

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

83.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start