29 0372_29 0371_07062022_025152.mp4
2 ft. - General Observation - PIPE IS NRCP
2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
12.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
127.4 ft. - Hole Void Visible, from 04 to 05 o'clock, within 8 inches of joint: YES
246.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"
350 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 6"
| Distance | Code | Observation |
|---|---|---|
| 458.1 | FM | — |
| 0 | MWM | — |
| 0 | AMH | 29 0372 |
| 12.3 | FM | — |
| 127.4 | HVV | — |
| 458.1 | MGO | CONNECTION AT MH 3 O'CLOCK |
| 458.1 | AMH | 29 0371 |
| 2 | MGO | PIPE IS NRCP |
| 117.3 | TF | — |
| 0 | MWL | — |
| 7 | FM | — |
| 181.7 | TF | — |
| 379.2 | TF | — |
| 2 | SAP | — |
| 458.1 | SAP | — |
| 277.6 | TF | — |
| 246.9 | TB | — |
| 350 | TB | — |