Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2022, 05:20 AM
  • 05 0481_05 2562_08092022_223321.mp4

Date
08/09/2022
W/O
966790
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00526
PipeID
P24991
Time
10:20 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10272
Sewer Name
05 STRAWBERRY AVENUE TRUNK
City
HAWTHORNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_966790_TV05379_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 0481
Downstream MH
05 2562
Dir. of Survey
Downstream
Length Surveyed
264.9 ft.
Total Length
264.9 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 05 0481 to 05 2562
MH: 05 0481MH: 05 2562downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 04810 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area4.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"16.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start35 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"45.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"84 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"85.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"126.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"131.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"164.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"184.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"204.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"234.1 ft. FM - Fracture Multiple, from 10 to 11 o'clock, within 8 inches of joint: YES235.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"245.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"264.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish264.9 ft. AMH - Downstream Manhole, Survey Ends - 05 2562

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    16.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 11 o'clock, within 8 inches of joint: YES

    234.1 ft. - Fracture Multiple, from 10 to 11 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
164.6TF
0AMH05 0481
235.2TF
184.4TF
204.7TF
234.1FM
35TF
245.5TF
131.4TF
264.2CM
264.9AMH05 2562
84TF
0MWM
0MWL
126.2TF
16.2CM
4.8TF
45.7TF
85.9TF

Properties (7)

additional_info
630074080922201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2022-08-09T22:20:25-07:00
documentation
PROPIPE
is_lateral_inspection
false