Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2022, 04:43 AM
  • 05 0482_05 0481_08092022_222003.mp4

Date
08/09/2022
W/O
966790
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00526
PipeID
P05697
Time
9:43 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10272
Sewer Name
05 STRAWBERRY AVENUE TRUNK
City
HAWTHORNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_966790_TV05379_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
18 in.
Upstream MH
05 0482
Downstream MH
05 0481
Dir. of Survey
Downstream
Length Surveyed
312 ft.
Total Length
312 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 05 0482 to 05 0481
MH: 05 0482MH: 05 0481downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 04820 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area9.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start23.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"38.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"76.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"92.3 ft. FM - Fracture Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES94 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"121.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"146.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"158.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"195.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"199.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"239.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"241 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"276.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"299.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"305.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish312 ft. AMH - Downstream Manhole, Survey Ends - 05 0481

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES

    92.3 ft. - Fracture Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
195.1TF
76.3TF
241TF
0AMH05 0482
23.1TF
0MWM
0MWL
38.5TF
305.9CM
121.9TF
92.3FM
312AMH05 0481
94TF
158.7TF
239.2TF
146.9TF
199.1TF
276.1TF
9.3CM
299.4TF

Properties (7)

additional_info
630074080922201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2022-08-09T21:43:52-07:00
documentation
PROPIPE
is_lateral_inspection
false