Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 3, 2022, 06:39 AM
  • 32 0083_32 0082_06032022_005749.mp4

Date
06/02/2022
W/O
957080
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00889
PipeID
P19846
Time
11:39 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10138
Sewer Name
32 RYE CANYON TRUNK
City
VALENCIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_957080_TV32051_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
32 0083
Downstream MH
32 0082
Dir. of Survey
Downstream
Length Surveyed
498.9 ft.
Total Length
498.9 ft.
Structural Index
3
Structural Quick
4224
Structural Rating
16
O&M Index
2
O&M Quick
2S00
O&M Rating
198
Overall Index
2
Overall Quick
Overall Rating
214
Pipe schematic from manhole 32 0083 to 32 0082
MH: 32 0083MH: 32 0082downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 00830 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.6 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES20 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"95.6 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES99.4 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"125.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES209.7 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES270.1 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES270.7 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"491.2 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES496.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish498.9 ft. AMH - Downstream Manhole, Survey Ends - 32 0082

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    4.6 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    95.6 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    125.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    209.7 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    491.2 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
209.7CL
0AMH32 0083
498.9AMH32 0082
491.2FM
125.6CL
20TFA
270.7TFA
0MWM
99.4TFA
0MWL
4.6FM
2DAGS
496.9DAGS
270.1CL
95.6CL

Properties (7)

additional_info
630063060222202
custom_field_three
FRACTURES/CRACKS
custom_field_two
2
customer
1
datetime
2022-06-02T23:39:50-07:00
documentation
PRO PIPE
is_lateral_inspection
false