Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2022, 08:13 AM
  • 05 1814B_05 1814A_08102022_011921.mp4

Date
08/10/2022
W/O
967394
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00466
PipeID
P24951
Time
1:13 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10273
Sewer Name
05 JANET LANE TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
31
Purpose
Routine Assessment
Project
RFIR_WO_967394_TV05329_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
05 1814B
Downstream MH
05 1814A
Dir. of Survey
Downstream
Length Surveyed
37.9 ft.
Total Length
37.9 ft.
Structural Index
4
Structural Quick
4431
Structural Rating
19
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
19
Pipe schematic from manhole 05 1814B to 05 1814A
MH: 05 1814BMH: 05 1814Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 1814B0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area9.6 ft. FM - Fracture Multiple, from 12 to 07 o'clock, within 8 inches of joint: YES10.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES22.7 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES30.3 ft. FM - Fracture Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES33.4 ft. FM - Fracture Multiple, from 02 to 06 o'clock, within 8 inches of joint: YES37 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK37.9 ft. AMH - Downstream Manhole, Survey Ends - 05 1814A

Observation photos (5)

  • Fracture Multiple, from 12 to 07 o'clock, within 8 inches of joint: YES

    9.6 ft. - Fracture Multiple, from 12 to 07 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    10.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    22.7 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

    30.3 ft. - Fracture Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 02 to 06 o'clock, within 8 inches of joint: YES

    33.4 ft. - Fracture Multiple, from 02 to 06 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
37MGOCONNECTION AT MH 3 O'CLOCK
37.9AMH05 1814A
0AMH05 1814B
10.4CM
33.4FM
30.3FM
22.7FM
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
9.6FM
0MWM

Properties (7)

additional_info
630074080922202
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-08-10T01:13:43-07:00
documentation
PROPIPE
is_lateral_inspection
false