Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2022, 09:17 AM
  • 05 1804_05 1803_08102022_023231.mp4

Date
08/10/2022
W/O
967394
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00466
PipeID
P07026
Time
2:17 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10273
Sewer Name
05 JANET LANE TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
31
Purpose
Routine Assessment
Project
RFIR_WO_967394_TV05329_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
21 in.
Upstream MH
05 1804
Downstream MH
05 1803
Dir. of Survey
Downstream
Length Surveyed
321.2 ft.
Total Length
321.2 ft.
Structural Index
4
Structural Quick
4200
Structural Rating
8
O&M Index
3
O&M Quick
4231
O&M Rating
12
Overall Index
3
Overall Quick
Overall Rating
20
Pipe schematic from manhole 05 1804 to 05 1803
MH: 05 1804MH: 05 1803downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 18040 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2.1 ft. FM - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES7.2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start100.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"162.1 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 20 %, within 8 inches of joint: YESR176.9 ft. RBL - Roots Ball Lateral, at 10 o'clock, 75 %176.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"203.4 ft. RBC - Roots Ball Connection, at 10 o'clock, 75 %203.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"305.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish319.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish321.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1803

Observation photos (8)

  • Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.2 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    100.7 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Roots Medium Joint, from 08 to 04 o'clock, 20 %, within 8 inches of joint: YESR

    162.1 ft. - Roots Medium Joint, from 08 to 04 o'clock, 20 %, within 8 inches of joint: YESR

  • Roots Ball Lateral, at 10 o'clock, 75 %

    176.9 ft. - Roots Ball Lateral, at 10 o'clock, 75 %

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    176.9 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Roots Ball Connection, at 10 o'clock, 75 %

    203.4 ft. - Roots Ball Connection, at 10 o'clock, 75 %

Observations (15)

DistanceCodeObservation
321.2AMH05 1803
176.9RBL
7.2RFJ
0AMH05 1804
0MWL
0MWM
2.1FM
176.9TF
162.1RMJ
203.4RBC
100.7TB
203.4TF
305.4RFJ
7.2FM
319.2FM

Properties (7)

additional_info
630074080922202
custom_field_three
FRACTURE'S/ROOTS
custom_field_two
2
customer
1
datetime
2022-08-10T02:17:44-07:00
documentation
PROPIPE
is_lateral_inspection
false