Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 16, 2022, 06:03 AM
  • 02 1040_02 1039_08152022_231930.mp4

Date
08/15/2022
W/O
967275
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00306
PipeID
P03611
Time
11:03 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10327
Sewer Name
02 TELEGRAPH ROAD TRUNK
City
COMMERCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
21
Purpose
Routine Assessment
Project
WO_967275_TV02432_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
24 in.
Upstream MH
02 1039
Downstream MH
02 1040
Dir. of Survey
Upstream
Length Surveyed
296.8 ft.
Total Length
296.8 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
177
O&M Index
2
O&M Quick
2K00
O&M Rating
118
Overall Index
3
Overall Quick
Overall Rating
295
Pipe schematic from manhole 02 1039 to 02 1040
MH: 02 1039MH: 02 1040upstream0 ft. RPZD - Repair Other Defective, within 8 inches of joint: YES - DAMAGED LINK PIPE0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - DUE TO DAMAGED LINK PIPE.0.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"53.4 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"107.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"154.8 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"181.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"235.9 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"283.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"288.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start294.8 ft. CM - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES294.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start296.8 ft. MWM - Water Mark, 20 %of cross sectional area296.8 ft. MWL - Water Level, 5 %of cross sectional area296.8 ft. AMH - Downstream Manhole, Survey Begins - 02 1039

Observation photos (5)

  • Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    2 ft. - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Repair Other Defective, within 8 inches of joint: YES - DAMAGED LINK PIPE

    296.8 ft. - Repair Other Defective, within 8 inches of joint: YES - DAMAGED LINK PIPE

  • Survey Abandoned - DUE TO DAMAGED LINK PIPE.

    296.8 ft. - Survey Abandoned - DUE TO DAMAGED LINK PIPE.

Observations (17)

DistanceCodeObservation
296.8RPZDDAMAGED LINK PIPE
13.5TFA
296.8CM
0MWM
296.3TFC
0MWL
8.4CM
0AMH02 1039
296.8DAGS
243.4TFC
189.6TFC
2CM
296.8MSADUE TO DAMAGED LINK PIPE.
115.5TFC
142TFC
60.9TFC
2DAGS

Properties (7)

additional_info
630098081522202
custom_field_three
CRACKS/DAMAGED LINK PIPE
custom_field_two
2
customer
1
datetime
2022-08-15T23:03:53-07:00
documentation
PRO PIPE
is_lateral_inspection
false