Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 1, 2022, 08:14 AM
  • 32 0229_32 0255_08012022_012045.mp4

Date
08/01/2022
W/O
962080
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00914
PipeID
P22506
Time
1:14 AM
Certificate
U-0720-70309212
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9999
Sewer Name
32 DISTRICT #32 MAIN RELIEF TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary
District
32
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_962080_TV32056_JUL2022
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Other
Height
36 in.
Upstream MH
32 0255
Downstream MH
32 0229
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 32 0255 to 32 0229
MH: 32 0255MH: 32 0229upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES0 ft. MSA - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.2 ft. AMH - Downstream Manhole, Survey Begins - 32 02552 ft. MWL - Water Level, 40 %of cross sectional area

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.

    2 ft. - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.

Observations (4)

DistanceCodeObservation
0AMH32 0255
2DAGS
0MWL
2MSAVIEW OF UPLEG OF D/S SIPHON.

Properties (7)

additional_info
630074080122001
custom_field_three
RFIR
custom_field_two
3
customer
LACSD
datetime
2022-08-01T01:14:11-07:00
documentation
PRO PIPE
is_lateral_inspection
false